RVEC00ECU Site Information Form (site log) International GPS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt 0. Form Prepared by (full name) : Sergio Alejandro Medina Valencia Date Prepared : 2025-04-03 Report Type : NEW If Update Previous Site Log : Modified/Added Sections : 1. Site Identification of the GNSS Monument Site Name : RIOVERDE ECUADOR Four Character ID : RVEC00ECU Monument Inscription : IERS DOMES Number : 42059M001 CDP Number : Monument Description : Concrete pillar built at top of the building with centering device on top. The station is installed in the facilities of the Gobierno Autónomo Descentralizado Municipal de Rioverde, Esmeraldas province. Height of the Monument : 2.40 m. Monument Foundation : roof Foundation Depth : (m) Marker Description : Date Installed : 2025-03-30T00:00Z Geologic Characteristic : Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : REGME (Red GNSS de Monitoreo Continuo del Ecuador-Instituto Geografico Militar-IGM Quito) 2. Site Location Information City or Town : Rioverde State or Province : Esmeraldas Country : ECU Tectonic Plate : South American Approximate Position (ITRF) X coordinate (m) : 1171641.396 Y coordinate (m) : -6268499.399 Z coordinate (m) : 118783.199 Latitude (N is +) : +010427.46 Longitude (E is +) : -0792446.93 Elevation (m,ellips.) : 31.454 Additional Information : REGME Network 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE ALLOY Satellite System : GPS+GLO+GAL+SBAS Serial Number : 6042R40114 Firmware Version : 6.23 Elevation Cutoff Setting : 0 Date Installed : 2025-03-30T00:00Z Date Removed : Temperature Stabiliz. : none Additional Information : REGME_EC Network 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM115000.00 NONE Serial Number : 60373G0024 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.000 Marker->ARP North Ecc(m) : 0.0 Marker->ARP East Ecc(m) : 0.0 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : LMR400 Antenna Cable Length : 30 m. Date Installed : 2025-03-30T00:00Z Date Removed : Additional Information : REGME_EC Network 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : GPS/GLONASS/GALILEO/BEIDOU Status : PERMANENT Effective Dates : 2025-04-01 Notes : 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.1 Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Instituto Geografico Militar Preferred Abbreviation : IGM Mailing Address : Av. Seniergues E4-676 y Gral. Telmo Paz y Miño Quito - Ecuador Apartado: 17-01-2435 Primary Contact Contact Name : Centro de Procesamiento de Datos GNSS CEPGE Telephone (primary) : +593 23 975 100 Ext 2241 Telephone (secondary) : Fax : E-mail : cepge.ecuador.igm@geograficomilitar.gob.ec Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : REGME 12. Responsible Agency (if different from 11.) Agency : Instituto Geografico Militar Preferred Abbreviation : IGM Mailing Address : Av. Seniergues E4-676 y Gral. Telmo Paz y Miño Quito - Ecuador Apartado: 17-01-2435 Primary Contact Contact Name : Centro de Procesamiento de Datos GNSS del Ecuador CEPGE Telephone (primary) : +593 23 975 100 Ext 2241 Telephone (secondary) : Fax : E-mail : cepge.ecuador.igm@geograficomilitar.gob.ec Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : Centro de Procesamiento de Datos GNSS del Ecuador - IGM (Quito-Ecuador) 13. More Information Primary Data Center : IGM (Instituto Geografico Militar) Secondary Data Center : CEPGE (Quito, Ecuador) URL for More Information : http://www.geoportaligm.gob.ec/portal/ Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : RED GNSS DE MONITOREO CONTINUO DEL ECUADOR 14. Antenna Graphics with Dimensions TRM115000.00 / --------------------------------------------- \ + + \ --------------------------------------------- / \ / \ / \-----+-----/ <-- 0.0000 BAM=ARP <-- 0.3396 --> Notches