Subject: [Sirgas-Mail] No.3898: PRMA : back online and data gap From: Sonia Maria Alves Costa Author: Sonia Costa Dear Colleagues, Station PRMA (Maringa) has new antenna and receiver since 24/05/2023. Data gap between days 120 to 143. 4. GNSS Antenna Information 4.4 Antenna Type : TRM59800.00 NONE Serial Number : 4938353434 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0080 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30 Date Installed : 2015-03-25T17:42Z Date Removed : 2023-05-24T14:00Z Additional Information : 4.5 Antenna Type : TRM59800.00 NONE Serial Number : 4940353510 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0080 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30 Date Installed : 2023-05-24T19:30Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : Best regards ================================================ Sonia Costa Coordenao de Geodsia - CGED Diretoria de Geocincias - DGC Instituto Brasileiro de Geografia e Estatstica - IBGE Tel: 21 21424985 ________________________________ Esta mensagem reservada. Sua divulgao, distribuio, reproduo ou qualquer forma de uso proibida e depende de prvia autorizao desta Instituio. O remetente utiliza o correio eletrnico no exerccio do seu trabalho ou em razo dele, eximindo esta Instituio de qualquer responsabilidade por utilizao indevida. Se voc recebeu esta mensagem por engano, favor elimin-la imediatamente. This message is reserved. Its disclosure, distribution, reproduction, or any other form of use is prohibited and shall depend upon previous proper authorization. The sender uses electronic mail in the exercise of his/her work or by virtue thereof, and the Institution accepts no liability for its undue use. If you have received this e-mail by mistake, please delete it immediately.

Author:  Sonia Costa

Dear Colleagues,

Station PRMA (Maringa) has new antenna and receiver since 24/05/2023.

Data gap between days 120 to 143.

 

4.   GNSS Antenna Information

 

4.4  Antenna Type             : TRM59800.00     NONE

     Serial Number            : 4938353434

     Antenna Reference Point  : BPA

     Marker->ARP Up Ecc. (m)  : 0.0080

     Marker->ARP North Ecc(m) : 0.0000

     Marker->ARP East Ecc(m)  : 0.0000

     Alignment from True N    : 0

     Antenna Radome Type      : NONE

     Radome Serial Number     :

     Antenna Cable Type       :

     Antenna Cable Length     : 30

     Date Installed           : 2015-03-25T17:42Z

     Date Removed             : 2023-05-24T14:00Z

     Additional Information   :

 

4.5  Antenna Type             : TRM59800.00     NONE

     Serial Number            : 4940353510

     Antenna Reference Point  : BPA

     Marker->ARP Up Ecc. (m)  : 0.0080

     Marker->ARP North Ecc(m) : 0.0000

     Marker->ARP East Ecc(m)  : 0.0000

     Alignment from True N    : 0

     Antenna Radome Type      : NONE

     Radome Serial Number     :

     Antenna Cable Type       :

     Antenna Cable Length     : 30

     Date Installed           : 2023-05-24T19:30Z

     Date Removed             : (CCYY-MM-DDThh:mmZ)

     Additional Information   :

 

Best regards

================================================

Sonia Costa

Coordenao de Geodsia – CGED

Diretoria de Geocincias - DGC

Instituto Brasileiro de Geografia e Estatstica - IBGE

Tel: 21 21424985

 


Esta mensagem reservada. Sua divulgao, distribuio, reproduo ou qualquer forma de uso proibida e depende de prvia autorizao desta Instituio. O remetente utiliza o correio eletrnico no exerccio do seu trabalho ou em razo dele, eximindo esta Instituio de qualquer responsabilidade por utilizao indevida. Se voc recebeu esta mensagem por engano, favor elimin-la imediatamente.


This message is reserved. Its disclosure, distribution, reproduction, or any other form of use is prohibited and shall depend upon previous proper authorization. The sender uses electronic mail in the exercise of his/her work or by virtue thereof, and the Institution accepts no liability for its undue use. If you have received this e-mail by mistake, please delete it immediately.