     RVEC00ECU Site Information Form (site log)
     International GPS Service
     See Instructions at:
       https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt

0.   Form

     Prepared by (full name)  : Sergio Alejandro Medina Valencia
     Date Prepared            : 2025-04-03
     Report Type              : NEW
     If Update
      Previous Site Log       : 
      Modified/Added Sections : 


1.   Site Identification of the GNSS Monument

     Site Name                : RIOVERDE ECUADOR
     Four Character ID        : RVEC00ECU
     Monument Inscription     : 
     IERS DOMES Number        : 42059M001
     CDP Number               : 
     Monument Description     : Concrete pillar built at
                                top of the building with
                                centering device on top.
                                The station is installed in the facilities of
                                the Gobierno Autónomo Descentralizado 
				Municipal de Rioverde,
				Esmeraldas province.
       Height of the Monument : 2.40 m.
       Monument Foundation    : roof
       Foundation Depth       : (m)
     Marker Description       : 
     Date Installed           : 2025-03-30T00:00Z
     Geologic Characteristic  : 
       Bedrock Type           : 
       Bedrock Condition      : 
       Fracture Spacing       : 
       Fault zones nearby     : 
         Distance/activity    : 
     Additional Information   : REGME (Red GNSS de Monitoreo Continuo del
                                Ecuador-Instituto Geografico Militar-IGM Quito)


2.   Site Location Information

     City or Town             : Rioverde
     State or Province        : Esmeraldas
     Country                  : ECU
     Tectonic Plate           : South American
     Approximate Position (ITRF)
       X coordinate (m)       : 1171641.396
       Y coordinate (m)       : -6268499.399
       Z coordinate (m)       : 118783.199
       Latitude (N is +)      : +010427.46
       Longitude (E is +)     : -0792446.93
       Elevation (m,ellips.)  : 31.454
     Additional Information   : REGME Network


3.   GNSS Receiver Information

3.1  Receiver Type            : TRIMBLE ALLOY
     Satellite System         : GPS+GLO+GAL+SBAS
     Serial Number            : 6042R40114
     Firmware Version         : 6.23
     Elevation Cutoff Setting : 0
     Date Installed           : 2025-03-30T00:00Z
     Date Removed             : 
     Temperature Stabiliz.    : none
     Additional Information   : REGME_EC Network
     
3.x  Receiver Type            : (A20, from rcvr_ant.tab; see instructions)
     Satellite System         : (GPS+GLO+GAL+BDS+QZSS+SBAS)
     Serial Number            : (A20, but note the first A5 is used in SINEX)
     Firmware Version         : (A11)
     Elevation Cutoff Setting : (deg)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Temperature Stabiliz.    : (none or tolerance in degrees C)
     Additional Information   : (multiple lines)


4.   GNSS Antenna Information

4.1  Antenna Type             : TRM115000.00    NONE
     Serial Number            : 60373G0024
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  : 0.000
     Marker->ARP North Ecc(m) : 0.0
     Marker->ARP East Ecc(m)  : 0.0
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : LMR400
     Antenna Cable Length     : 30 m.
     Date Installed           : 2025-03-30T00:00Z
     Date Removed             : 
     Additional Information   : REGME_EC Network

4.x  Antenna Type             : (A20, from rcvr_ant.tab; see instructions)
     Serial Number            : (A*, but note the first A5 is used in SINEX)
     Antenna Reference Point  : (BPA/BCR/XXX from "antenna.gra"; see instr.)
     Marker->ARP Up Ecc. (m)  : (F8.4)
     Marker->ARP North Ecc(m) : (F8.4)
     Marker->ARP East Ecc(m)  : (F8.4)
     Alignment from True N    : (deg; + is clockwise/east)
     Antenna Radome Type      : (A4 from rcvr_ant.tab; see instructions)
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


5.   Surveyed Local Ties

5.x  Tied Marker Name         : 
     Tied Marker Usage        : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : (m)
       dy (m)                 : (m)
       dz (m)                 : (m)
     Accuracy (mm)            : (mm)
     Survey method            : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
     Date Measured            : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


6.   Frequency Standard

6.x  Standard Type            : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
     Input Frequency          : (if external)
     Effective Dates          : (CCYY-MM-DD/CCYY-MM-DD)
     Notes                    : (multiple lines)


7.   Collocation Information

7.1  Instrumentation Type     : GPS/GLONASS/GALILEO/BEIDOU
       Status                 : PERMANENT
       Effective Dates        : 2025-04-01
       Notes                  : 


7.x  Instrumentation Type     : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
       Status                 : (PERMANENT/MOBILE)
     Effective Dates          : (CCYY-MM-DD/CCYY-MM-DD)
     Notes                    : (multiple lines)


8.   Meteorological Instrumentation

8.1.1 Humidity Sensor Model   : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.1.x Humidity Sensor Model   : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.1 Pressure Sensor Model   : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.x Pressure Sensor Model   : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.1 Temp. Sensor Model      : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.x Temp. Sensor Model      : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.1 Water Vapor Radiometer  : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.x Water Vapor Radiometer  : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.5.1 Other Instrumentation   : (multiple lines)

8.5.x Other Instrumentation   : (multiple lines)


9.  Local Ongoing Conditions Possibly Affecting Computed Position

9.1.1 Radio Interferences     : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.1.x Radio Interferences     : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.1 Multipath Sources       : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.x Multipath Sources       : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.1 Signal Obstructions     : (TREES/BUILDLINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.x Signal Obstructions     : (TREES/BUILDLINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

10.  Local Episodic Effects Possibly Affecting Data Quality

10.1 Date                     : (CCYY-MM-DD/CCYY-MM-DD)
     Event                    : (TREE CLEARING/CONSTRUCTION/etc)

10.x Date                     : (CCYY-MM-DD/CCYY-MM-DD)
     Event                    : (TREE CLEARING/CONSTRUCTION/etc)


11.  On-Site, Point of Contact Agency Information

     Agency                   : Instituto Geografico Militar
     Preferred Abbreviation   : IGM
     Mailing Address          : Av. Seniergues E4-676 y Gral. Telmo Paz y Miño
                                Quito - Ecuador
                                Apartado: 17-01-2435     
    Primary Contact
       Contact Name           : Centro de Procesamiento de Datos GNSS CEPGE
       Telephone (primary)    : +593 23 975 100 Ext 2241
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : cepge.ecuador.igm@geograficomilitar.gob.ec
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : REGME


12.  Responsible Agency (if different from 11.)

     Agency                   : Instituto Geografico Militar
     Preferred Abbreviation   : IGM
     Mailing Address          : Av. Seniergues E4-676 y Gral. Telmo Paz y Miño
                                Quito - Ecuador
                                Apartado: 17-01-2435     
     Primary Contact
       Contact Name           : Centro de Procesamiento de Datos GNSS del Ecuador CEPGE
       Telephone (primary)    : +593 23 975 100 Ext 2241
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : cepge.ecuador.igm@geograficomilitar.gob.ec
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : Centro de Procesamiento de Datos GNSS del 
                                Ecuador - IGM (Quito-Ecuador)


13.  More Information

     Primary Data Center      : IGM (Instituto Geografico Militar)
     Secondary Data Center    : CEPGE (Quito, Ecuador)
     URL for More Information : http://www.geoportaligm.gob.ec/portal/
     Hardcopy on File
       Site Map               : 
       Site Diagram           : 
       Horizon Mask           : 
       Monument Description   : 
       Site Pictures          : 
     Additional Information   : RED GNSS DE MONITOREO CONTINUO DEL ECUADOR


14. Antenna Graphics with Dimensions


 TRM115000.00

  
     / --------------------------------------------- \
    +                                                 +
     \ --------------------------------------------- /
                     \               /
                      \             /
                       \-----+-----/                        <--  0.0000  BAM=ARP
  
  <--                    0.3396                   -->                  Notches
